Conductive point level switch, Output: 2 x SPDT relay, Process temperature range: -20–60°C, Auxiliary power: 85–253 V AC/20–30 V AC/20–60 V DC, Protection rating: IP66
Conductive level detector, Media: liquid with minimum conductivity of up to 10 µS/cm, Max. probe length: 15 m, Output: PNP/Relay/NAMUR/separate electronic, Process pressure range: -1–10 bar, Measuring points: 2/3/5, Process temperature range: -40–70 °C, Protection rating: IP66
Capacitive level sensors, Media: liquid with minimum conductivity of up to 100 µS/cm , Max. probe length: 2,500 mm, Output: 4-20 mA, Process pressure range: -1–10 bar, Process temperature range: -40–100 °C, Measuring accuracy: ± 1 %, Probe material: stainless steel (1.4404) or carbon fibre, Enclosure material: polyester, Protection rating: IP66, With overfill protection as per WHG
Conductive point level switch, Functions: two-channel fill-level analysis / level / switch delay / two-point control, Switching output: 1 x Relay SPDT, Auxiliary energy: 20–30 V AC/20–60 V DC, Dimensions: 35 x 99 x 102.5 mm, Operating temperature: -20–60 °C, Mounting: DIN 35 rails
Conductive point level switch, Functions: two-channel level measurement / level limit / switch delay / two-point control, Switching output: 2 x SPDT relays, Power Supply: 85-253 V AC, Dimensions: 35 x 99 x 102.5 mm, Operating temperature: -20–60 °C, Mounting: DIN 35 rails
Conductive point level switch, Functions: Two-channel level evaluation / limit level / switching delay / two-point control, Switching output: 2 x SPDT relays, Power supply: 20...30 V AC / 20...60 V DC, Dimensions: 35 x 99 x 102.5 mm, Ambient temperature: -20...60 °C, ATEX approval, Mounting: DIN rail35
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measurement point: 3 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measurement point: 3 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland, Water Resources Act (WHG)/leakage monitoring
Conductive level detector, rod probe, Media: conductive liquids, Probe length: 1000 mm, Measuring point: 5 x rod (stainless steel), Output: Separate instrumentation (FTW325), 3-wire, Pressure measuring range: -1...10 bar, Process temperature range: -40...100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable glands
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 1,000 mm, Measuring point: 2 x rod (stainless steel), Output: Separate instrumentation (FTW325), 3-wire, Pressure measuring range: -1...10 bar, Process temperature range: -40...100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable glands, WHG/ leakage monitoring, Approval: ATEX/ WHG/ XA
Conductive point level switch, functions: Two-channel level evaluation / limit level / switching delay / two-point control, Switching output: 2 x relay SPDT, Power supply: 85...253 V AC, Dimensions: 35 x 99 x 102.5 mm, Ambient temperature: -20...60 °C, Mounting: DIN rail 35, ATEX approval
Conductive point level detector, rod probe, Media: conductive liquids, Probe length: 1,500 mm, Measuring point: 5 x rod (stainless steel), Output: Separate instrumentation (FTW325), 3-wire, Pressure measuring range: -1...10 bar, Process temperature range: -40...100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable glands
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G1, Connection: M12 plug connection
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G3/4, Connection: M12 plug connection
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 5,000 mm, Measurement point: 3 x rod (316Ti), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Order item – will be ordered from the manufacturer on demand
Dispatch expected in 8 working days
The product will be ordered individually for you from the manufacturer and can therefore not be returned. It will be dispatched as quickly as possible.
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 5,000 mm, Measurement point: 5 x rod (316Ti), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland
Order item – will be ordered from the manufacturer on demand
Dispatch expected in 12 working days
The product will be ordered individually for you from the manufacturer and can therefore not be returned. It will be dispatched as quickly as possible.
Conductive point level detector, Rod probe, Media: conductive liquids, Probe length: 2,000 mm, Measurement point: 5 x rod (stainless steel), Output: separate instrumentation (FTW325), 3-wire, Pressure measurement range: -1–10 bar, Process temperature range: -40–100 °C, Protection rating: IP66, Process connection: G 1 1/2, Connection: M20 cable gland, Water Resources Act (WHG)/leakage monitoring
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65, Process connection: G1, Connection: M16 valve connector ISO4400
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, IO-Link, 3-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65, Process connection: G1/2, Connection: M16 valve connector ISO4400
Conductive point level detector, Hygienic, Media: water and oil-based, Output: DC-PNP, 4-wire, Power supply: 10–30 V DC, Pressure measurement range: -1–25 bar, Process temperature range: -20–100 °C, Protection rating: IP65/IP67, Process connection: G3/4, Connection: M12 plug connection
Order item – will be ordered from the manufacturer on demand
Dispatch expected in 9 working days
The product will be ordered individually for you from the manufacturer and can therefore not be returned. It will be dispatched as quickly as possible.
We use cookies
Our online store uses cookies to help us improve our offer and provide the best possible service to our customers. By clicking "Accept" you agree to our cookie policy.
Cookies for tools that collect anonymous data about website usage and functionality. We use the insights to improve our products, services and user experience.
Advertising
Cookies for product recommendations and the display of relevant advertising. We and our partners, including Google, may use anonymized browsing data for personalized advertising and analytical purposes. For more information, please refer to the Google Business Privacy section.
Essential cookies
Cookies for tools that enable essential services and functions. This option cannot be declined.