Monitoring relay, Features: Monitoring and protection of phase sequence/phase failure/phase imbalance for 3-phase systems, Alarm output: 1 x NO/NC, Supply voltage: 154-500 V AC, Dimensions: 17.5 x 90 x 60 mm, Mounting: 35 mm DIN-rail, Terminal connection
Monitoring relay, Features: Undervoltage/Overvoltage protection for 1 and 3-phase systems, Time functions: Power ON/Tripping/Response time delay, Additional features: Alarm display; Reset. Analogue, Input voltage: 230 V AC, Dimensions: 35 x 90 x 60 mm, Mounting: 35 mm DIN-rail, Terminal connection
Monitoring relay for 3 phase networks, Features: Undervoltage monitoring for AC voltage in 3-phase networks/Phase sequence/Phase failure and asymmetry monitoring with adjustable asymmetry, Connection of the neutral conductor optional, Tripping delay: fixed/approx. 100 ms, Rated voltage: 250 V AC, 1 x Change over contact, Terminal connection
Monitoring relay for 1 and 3 phase networks, Features: Undervoltage monitoring (UNDER)/Undervoltage and phase sequence monitoring (UNDER+SEQ)/Monitoring of the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0-10 s, 1 x changeover contact, Rated voltage: 250 V AC, Terminal connection
Monitoring relays, functions: Monitoring and protection of phase failure, overvoltage and undervoltage in window mode for 3-phase systems, 2 x changeover contacts, measuring voltage limits: 114...329 V AC, dimensions: 35 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure, phase asymmetry (5-15%), overvoltage and undervoltage (2-20%) for 3-phase systems, 1 x changeover contact, supply voltage from the measuring circuit: 183...528 V AC, dimensions: 17.5 x 90 x 72 mm, mounting: DIN rail DIN 35, screw terminals
Voltage frequency monitoring relay, functions: Monitoring for frequency fluctuations, 1x changeover contact overshoot, 1 x changeover contact undershoot, Supply voltage limits: 102...308 V AC, Dimensions: 35 x 90 x 72 mm, Mounting: DIN rail DIN 35, screw terminals
Monitoring relay for 1 and 3 phase networks, Features: Voltage monitoring with adjustable thresholds/adjustable tripping delay/monitoring of phase failure; Phase sequence and asymmetry with adjustable asymmetry/Undervoltage monitoring (UNDER)/Undervoltage monitoring and monitoring of phase sequence (UNDER+SEQ)/Monitoring the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0-30 s, 2 x change over contacts, Rated voltage: 250 V AC, Terminal connection
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure, phase asymmetry (5-15%), overvoltage and undervoltage in window mode (-20--2%/+2-+20% depenDINg on voltage) for 3-phase systems, 2 x changeover contacts, measuring voltage limits: 176...528 V AC, dimensions: 35 x 90 x 72 mm, mounting: DIN rail DIN 35, screw terminals
Voltage frequency monitoring relay, NFC-capable, functions: Phase sequence, phase fault detection, overvoltage detection, undervoltage detection, over and under mains frequency, asymmetry, 2 x changeover contacts, Supply voltage limits: 166.4...576 V AC phase to phase / 96...332.4 V AC phase to neutral, Dimensions: 35 x 90 x 72 mm, Mounting: DIN rail DIN 35, screw terminals, Requires app: ‘Ecostruxure Industrial Device’
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure and undervoltage (2-20%) for 3-phase systems, 2 x changeover contacts, supply voltage from the measuring circuit: 304...576 V AC, dimensions: 22.5 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence and phase failure for 3-phase systems, 2 x changeover contacts, supply voltage from the measuring circuit: 183...528 V AC, dimensions: 17.5 x 90 x 72 mm, mounting: DIN rail DIN 35, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure and phase asymmetry (5-15%) for 3-phase systems, 2 x changeover contacts, supply voltage from the measuring circuit: 304...576 V AC, dimensions: 22.5 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence & phase failure for 3-phase systems, 1 x changeover contact, supply voltage from the measuring circuit: 183...528 V AC, dimensions: 17.5 x 90 x 72 mm, mounting: DIN rail 35, screw terminals
Monitoring relays, functions: Monitoring and protection of overvoltage and undervoltage (2-20%) for 1-phase systems, measuring range: 15...500 V AC/DC, 2 x changeover contacts, supply voltage: 20.4 ...264 V AC, dimensions: 22.5 x 90 x 72 mm, mounting: DIN 35 DIN rails, screw terminals
Monitoring relay for 1 phase networks, Fusing: 8 A fast acting, Features: Undervoltage monitoring (U)/Window function (WIN), Time functions: Start-up delay approx. 300 ms/Tripping delay 0.1-10 s, 1 x changeover contact, 24 V DC/230 V AC/DC, Terminal connection
Order item – will be ordered from the manufacturer on demand
Dispatch expected in 18 working days
The product will be ordered individually for you from the manufacturer and can therefore not be returned. It will be dispatched as quickly as possible.
Monitoring relay for 3 phase networks, Fusing: 5 A fast acting, Features: Undervoltage monitoring (UNDER)/Undervoltage and phase sequence monitoring (UNDER+SEQ)/Monitoring of the window between Min and Max (WIN)/Monitoring of the window between Min and Max and monitoring of phase sequence (WIN+SEQ), Tripping delay: 0.1-10 s, 2 x changeover contacts, 24-240 V AC/DC, Terminal connection
Order item – will be ordered from the manufacturer on demand
Dispatch expected in 6 working days
The product will be ordered individually for you from the manufacturer and can therefore not be returned. It will be dispatched as quickly as possible.
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure and phase asymmetry (5-15%) for 3-phase systems, 1 x changeover contact, supply voltage from the measuring circuit: 183...528 V AC, dimensions: 17.5 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure and overvoltage and undervoltage (2-20%) for 3-phase systems, 2 x changeover contacts, supply voltage from the measuring circuit: 304...576 V AC, dimensions: 22.5 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase failure, overvoltage and undervoltage in window mode (-20--2%/+2-+20% depenDINg on voltage) for 3-phase systems, 2 x changeover contacts, measuring voltage limits: 194...528 V AC, dimensions: 35 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Monitoring relays, functions: Monitoring and protection of phase sequence, phase failure and undervoltage (2-20%) for 3-phase systems, 1 x changeover contact, supply voltage from the measuring circuit: 183...528 V AC, dimensions: 17.5 x 90 x 72 mm, mounting: DIN 35 rails, screw terminals
Our online store uses cookies to help us improve our offer and provide the best possible service to our customers. By clicking "Accept" you agree to our cookie policy.
Cookies for tools that collect anonymous data about website usage and functionality. We use the insights to improve our products, services and user experience.
Advertising
Cookies for product recommendations and the display of relevant advertising. We and our partners, including Google, may use anonymized browsing data for personalized advertising and analytical purposes. For more information, please refer to the Google Business Privacy section.
Essential cookies
Cookies for tools that enable essential services and functions. This option cannot be declined.